Quitadamo P, Tambucci R, Mancini V, Cristofori F, Baldassarre M, et al. Esophageal pH-impedance monitoring in children: position paper on indications, methodology and interpretation by the SIGENP working group. Dig Liver Dis. 2019 Nov;51(11):1522-1536.
Esophageal pH-impedance monitoring in children: position paper on indications, methodology and interpretation by the SIGENP working group Paolo Quitadamoa,b,*, Renato Tambuccic,d, Valentina Mancinie, Fernanda Cristoforif,
a Department of Pediatrics, A.O.R.N. Santobono-Pausilipon, Naples, Italy b Department of Translational Medical Science,“Federico II”, University of Naples, Italy c Digestive Endoscopy and Surgery Unit, Bambino Gesù Children’s Hospital, IRCCS, Rome, Italy d Department of Biotechnological and Applied Clinical Sciences, University of L’Aquila, L’Aquila, Italy e Department of Pediatrics and Neonatology, Saronno Hospital, Saronno, Italy f Department of Pediatrics, Giovanni XXIII Hospital, Aldo MoroUniversity of Bari, Bari, Italy g Department of Biomedical Science and Human Oncology-neonatology and Nicu section, University “Aldo Moro”, Bari, Italy h Department of Medical and Surgical Sciences, Pediatric Unit, University “Magna Graecia” of Catanzaro, Catanzaro, Italy i NESMOS Department, School of Medicine and Psychology, Sapienza University of Rome, Sant’Andrea University Hospital, Rome, Italy j Department of Pediatrics, Pediatric Gastroenterology and Liver Unit, Sapienza University of Rome, Rome, Italy k Neonatology and Neonatal Intensive Care Unit, Department of Public Health and Pediatrics, University of Turin, Turin, Italy l Pediatric Department, Ospedale ¨F. Del Ponte¨ , University of Insubria, Varese, Italy m Division of Neurogastroenterology and Motility, Department of Paediatric Gastroenterology, UCL Institute ofChild Health and Great OrmondStreet Hospital, London, UK PMID: 31526716 DOI: 10.1016/j.dld.2019.07.016 Краткое изложение на русском языке AbstractMultichannel intraluminal impedance pH (MII-pH) monitoring currently represents the gold standard diagnostic technique for the detection of gastro-esophageal reflux (GER), since it allows to quantify and characterize all reflux events and their possible relation with symptoms. Over the last ten years, thanks to its strengths and along with the publication of several clinical studies, its worldwide use has gradually increased, particularly in infants and children. Nevertheless, factors such as the limited pediatric reference values and limited therapeutic options still weaken its current clinical impact. Through an up-to-date review of the available scientific evidence, our aim was to produce a position paper on behalf of the working group on neurogastroenterology and acid-related disorders of the Italian Society of Pediatric Gastroenterology, Hepatology and Nutrition (SIGENP) on MII-pH monitoring technique, indications and interpretation in pediatric age, in order to standardise its use and to help clinicians in the diagnostic approach to children with GER symptoms.Keywords: Children; Gastro-esophageal reflux; Infants; pH-impedance. On behalf of the working group on Neurogastroenterology and Acid-related Disorders of the Italian Society for Pediatric Gastroenterology, Epatology, and Nutrition (SIGENP) * Corresponding author at: Department of Pediatrics, A.O.R.N. Santobono-Pausilipon, Via Mario Fiore 6, 80100 Naples, Italy. E-mail address: paoloquitadamo@ yahoo.it (P. Quitadamo). 1. IntroductionMultichannel intraluminal impedance pH (MII-pH) monitoring currently represents the gold standard diagnostic technique for the detection of gastro-esophageal reflux (GER), since it allows to quantify and characterize all reflux events and their possible relaion with symptoms [1]. MII-pH monitoring provides an accurate assessment of the number of both acid and non acid GER episodes, the acid esophageal exposure percent time, the height and composition of the refluxate (liquid, gas, or mixed contents). It also recognizes swallows from reflux episodes, measures the bolus and acid clearance time, and assesses the temporal association between reflux episodes and symptoms occurring during the study period. Over the last ten years, thanks to its strengths and along with the publication of several clinical studies its worldwide use has gradually increased, particularly in infants and children.Although MII-pH monitoring provides a great amount of esophageal data, yet the limited reference and normative values, the lack of therapeutic choices for non acid GER and the cost of the device and catheters currently reduce its clinical impact. The aim of the current paper is to present an updated summary of MII-pH monitoring technique, indications, and interpretation in pediatric age to help clinicians in the diagnostic approach to children with GER disease. Therefore, an exhaustive search for eligible studies was performed in MEDLINE (via PubMed), EMBASE and Cochrane Library databases. The following headings were used: “pH monitoring technique”, “gastroesophageal reflux”, “multichannel intraluminal impedance (MII) pH monitoring technique”. Proper Boolean operators “AND” “OR” were also included to be as comprehensive as possible. English language restriction was applied while geographical restrictions were not. All relevant articles detected were further scrutinized for additional references which did not appear in the initial search. Search limits were set for studies on human subjects published between January 1990 and December 2018. When the scientific evidence was lacking, the reccomendations were formulated according to the authors’ personal experience. 2. Technical and methodological aspectsMII-pH monitoring was first described by Silny et al. in 1991 for the study of esophageal motility, providing information on the presence of esophageal bolus movements and type of esophageal content (solids, liquids, gas) by changes in intraluminal electrical conductivity [2]. The basic component of MII technology is an impedance circuit, including an alternating current generator (located in the recording device) and multiple metal rings placed across a catheter, which acts as an electrical isolator. The electrical circuit is closed by electrical charges in the esophageal mucosa surrounding the catheter.The test is based on the measurement of impedance (changes in resistance to electrical current in a circuit), which is inversely correlated to the ionic concentration of luminal content. A liquid bolus with a high ionic content (e.g. swallows, refluxate) has a high conductivity and therefore a low impedance measure, whilst in the presence of air the content of ions is low, resulting in a poor conductivity and hence a high impedance. At rest, in an empty esophagus, the conductivity and the so called baseline impedance are stable, ranging between 2000 and 4000 ohm. When a liquid bolus enters the esophagus, the impedance rapidly drops and remains low as long as the bolus lies between the 2 electrodes, then raises and returns to the baseline values once the bolus has passed (Fig. 1). In the presence of a gas bolus, a typical impedance spike above 5000 ohm is observed.
The presence of multiple channels on the same catheter allows the measurement of sequential transitory impedance changes (drop or rise) involving consecutive channels, determines the direction of bolus flow, and hence allows to discriminate between antegrade flow (swallow) from retrograde movement from the stomach (reflux) as well as the esophageal location (height) of the refluxate. Combining MII with pH monitoring enables the identification and classification of acidic (pH < 4), weakly acidic (pH 4–7) and weakly alkaline (pH > 7) episodes (Fig. 2).
3. The recording deviceMany ambulatory and stationary devices from different brands are now available and used in children of all ages. Portable ambulatory devices are very small and allow recording during normal daily activities and sleeping period. These devices, which are the most commonly used, are comfortable for the patients and have a simple interface with internal clock, event buttons and recumbent indicators for easy viewing. Conversely, stationary devices are less comfortable but enable to evaluate additional parameters, such as heart and respiratory rate, oxygen saturation, and esophageal motility with high-resolution manometry. Each device has specific catheters [3].4. CathetersMII-pH catheters are thin flexible polyvinyl catheters usually 2.13 mm diameter-wide (6.4 Fr). Single or multiple-use catheters are available and can be used according to investigator or patient choices, national regulations, and hygiene protocols. Multiple-use catheters must be sterilized according to the manufacturer’s recommendations. Therefore disposable catheters are often preferred. Catheters have 7–12 impedance rings/sensors positioned along the length of the catheters resulting in 6–11 corresponding impedance channels, as every channel is created by two consecutive rings/sensors. Various age (height)-appropriate impedance catheters are available: infant (height <75 cm), pediatric (height >75 cm and <150 cm), and adult (height >150 cm) type. The probes differ for the spacing between the impedance rings and the position of the pH sensor. In infant catheters, the space between two electrodes is 1.5 cm, whist in pediatric and adult catheters the distance is 2 cm due to the increased esophageal length. Combined MII-pH and (simplified) manometry catheters have been developed and may provide important additional information in selected patients (e.g. children with chronic cough or candidates to anti-reflux surgery).5. pH electrodesMII-pH catheters include 1 or 2 pH electrodes (for proximal and distal esophagus, esophageal and gastric, or pharyngeal and esophageal or gastric monitoring). Many different pH electrodes are commercially available, based on antimony, glass, ion-sensitive field-effect transistor (ISFET), each with their own advantages and disadvantages. However, although antimony electrodes are less sensitive than glass or ISFET electrodes, these are the most frequently used because of lower costs, ease to use characteristics, and smaller size. Differently from adult catheters, both in infant and pediatric catheters the pH sensor lies in the middle of the most distal impedance channel.6. Calibration of the catheterA correct calibration of the catheter is critical for an accurate registration of pH and impedance changes. The MII-pH catheter should be calibrated according to the manufacturer’s instructions, clearly displayed on the screen during the procedure, with 2 different buffer solutions (usually pH 4.0 and 7.0) at either room or body temperature, until stabilization is reached. If the catheter has the external reference, the calibration has to be done with the external reference electrode fixed on the skin of the child, and his finger immersed in the buffer solution together with the electrode. This method is not necessary for catheters with internal reference electrodes which are nowadays preferred.7. Computer softwareMII monitoring data can be manually read or automatically analysed by software. Several analytical software packages from different manufacturers are currently available. The software provides summary data for reflux occurrence and clearance, as well as calculations of symptom reflux temporal association indexes.The new software also supplies additional functions that magnifies, colours, and improves the vision of each event helping the observer to distinguish artefacts, swallowing and reflux. It also calculates the mean esophageal impedance value of all tracing or selected periods and segmental or total bolus transit time during swallowing. Moreover, nowadays wireless Bluetooth® technology may be applied to view data while recording. 8. Indications for testingDespite its acknowledged drawbacks, the role of MII-pH monitoring has gradually increased over the last years, especially in children in the early stages of life. MII-pH currently represents the gold standard diagnostic technique for measuring acid and non acid GER and symptom association, thus tailoring therapeutic intervention. Nevertheless, due to its burden in terms of patient discomfort, time analysis and costs, the indications for testing should be carefully evaluated. Combining NICE [4], ESPGHAN and NASPGHAN recommendations [1] MII-pH monitoring should be considered for the following conditions:
As MII-pH monitoring detects reflux irrespective of pH, it can be carried out on or off reflux therapy such as acid inhibitors [20]. Furthermore, children on enteral nutrition fed via continuous or bolus regimen can be accurately tested only with MII-pH, because of the majority of non acid GER episodes due to the buffering effect of feeding. Because MII-pH cannot determine and distinguish mucosal complications, upper endoscopy should also be performed in cases of suspect esophagitis, stenosis or Barrett esophagus. 9. Preparation of the patient and positioning of the probe9.1. Preparation of the patientBefore starting MII-pH monitoring is important to assess and report any clinical information about patient’s medical treatment and diet. In particular, histamine H2 receptor antagonist (H2 blockers) and prokinetics should be stopped at least 72 h before the study, whereas alginates can be suspended up to 4 h before the investigation [1]. The washout period must be prolonged for at least 2 weeks for proton pump inhibitors (PPIs) if the test would be performed off acid treatment for diagnostic purposes. H2-blockers or PPIs should be continued only when the MII-pH monitoring is performed to evaluate their effectiveness on esophageal acid exposure and to titrate the appropriate dose for the individual patient based on associated symptoms. Although various medications can alter LES function and esophageal pH (such as diazepam, smooth muscle relaxants, antiasthmatic drugs, etc.), their cessation is not necessary. The procedure should be carefully explained to parents and possibly to the child (if he/she is old enough) to obtain the child’s collaboration and to increase his/her comfort. Infants must be fasting for at least 3 h and children from at least 6 h before the procedure, to avoid nausea, vomiting, and aspiration during the insertion of the catheter. Before starting MII-pH testing, a written informed consent should be obtained from the parents. 9.2. Positioning of the probe The catheter is passed transnasally, preferably without sedation. Intranasal anesthetic spray or gel could be used to decrease child’s discomfort during the insertion. It is advised not to place the gel directly on the electrodes or metallic rings to avoid inaccuracy of recording. The pH probe tip should be ideally positioned in the lower esophagus at 87% of the total esophageal length, in order to avoid the LES region and the displacement into the stomach during the registration. The tip position is crucial for the correct measurement of pH and the detection of acid reflux episodes. Several methods have been suggested to identify the correct placement of pH electrodes: calculation of esophageal length, fluoroscopy, manometry, and endoscopy. Manometry is the most accurate method for localizing the LES and defining pH probe placement, but its use is very limited since it is invasive, time-consuming, and not widely available. Endoscopy may be necessary for the esophageal assessment and directly localizes the LES. However, it is invasive, not easily available, |